Burner and associated deviceOther accessories supporting parts

Ball valve

[ Features ]
It is an airtight, highly pressure resistant ball valve.
It is designed to have the same full bore as the nominal diameter of piping, so it is optimum for multiple flow rate.



Kitz butterfly valve

[ Features ]
It is an airtight, highly pressure resistant valve.
You can fix the handle after determining the opening degree.



Needle valve

[ Features ]
The body is a forged finish, and because it is a bonnet-less type, it is compact.
Because the shape of the valve is a needle, the flow rate can be adjusted.
Designed with an emphasis on operability, the handle torque is low and the structure is good with sealability.



Limiting valve

[ Features ]
When combustion adjustment of the gas burner, It is used to adjust the flow rate of gas / air, to make pressure loss, etc.



Strainer

[ Features ]
Use a built-in tubular metal mesh filter to stop the dust inside the gas pipe.
You can clean the dirty filter by removing the cap in the diagonal direction.

GMF type governor (Non relief specification)

[ Features ]
This governor is a medium type pressure governor with a flanged body, which is a compact design in which the flange part and the main body are integrated, and it fits neatly even in small spaces.



NGX type governor (Built-in abnormal boost prevention mechanism)

[ Features ]
Lightweight, mountable, built-in abnormal pressure rise prevention mechanism (high cut valve).
Moreover, it has built-in filter.
It is an NGX governor pursuing more safety.



Low pressure supply regulator

[ Features ]
This regulator reduces the outlet pressure to 20 kPa or less.
There are 2 types of 1 type and 2 type depending on the inlet pressure.

[ Model]
C-10A-1 (1 type)
C-10A-2 (2 type)



C・N type Governor

[ Specifications]
Primary pressure P1 = 30~500 kPa
Secondary pressure P2 = 0.5~30 kPa
Hole diameter = 1/2~ 2 B (15~50 A)

[ Model]
C13N~C50N-200-1 - Popular type



AH type Governor

[ Specifications]
Primary pressure P1 = 30~300 kPa
Secondary pressure P2 = 2~20 kPa
Hole diameter = 1・1/2~3 B (4~80 A)

[ Model]
AH40N~AH75N-11 - Popular type



C-N-6D type Governor

[ Specifications]
Primary pressure P1 = 30 ~1060 kPa
Secondary pressure P2 = 1 ~ 30 kPa
Hole diameter = 3/4~ 2 B (20~ 50 A)

[ Model]
C20N~ C50N-6D - Popular type



SGX-Z Zero governor

[ Features ]
It has a large capacity with respect to the hole diameter, and a stable outlet pressure can be obtained over a wide flow range.
Even if the flow rate used changes, the supplied outlet pressure is kept constant and stable combustion is maintained



A・N type Governor

[ Specifications]
Primary pressure P1 = 1 - 50 kPa
Secondary pressure P2 = 0 kPa
Hole diameter = 1/4- 3B (8- 80 A)

[ Model]
A8Z~ A50Z-1 type ... Popular type
A 20 Z~ A 50 Z - 2 type ... High performance type
A 40 Z~ A 75 Z - 11 type ... Large capacity type



A.N.D. type Governor

[ Specifications]
Primary side pressure P1=1?50kPa
Secondary side pressure P2=0.5~30kPa
Hole Diameter=2~3B(50~80A)

[ Model]
A50N~6D…High preformance type
A50N~A75N-51D…Large Capacity type



SGX.Z Governor

[ Features ]
Gas Zero Governor (pressure equalizing valve)is often used for various combustion methods for improving thermal efficiency, such as saving labor in heat management, etc., as large-scale gas combustion equipment that consumes a large amount of gas is remarkable.
It is used in pair with SHOEI's Venturi Mixer(VM).



A-Z Zero Governor

[ Specifications]
Primary side pressure P1=0.5~20kPa
Secondary side pressure P2=0kPa
Hole Diameter=1/4~3B(8?80A)

[ Model]
A8Z~A50Z-1…Popular type
A20Z~A50Z-2…High performance type
A40Z~A75Z-11…Large Capacity type



A・Z・D Zero governor

[ Specifications]
Primary pressure P1 = 0.5 - 20 kPa
Secondary pressure P2 = 0 kPa
Hole diameter = 2- 3B (50- 80 A)

[ Model]
A 50 Z~6D type ... High performance type
A 50 Z~ A 75 Z -51D ... Large capacity type


A・P type Equalizing valve

[ Specifications]
Primary pressure P1 = - 20 kPa
Secondary pressure P2 = 0 Pa(PL=P2)
Hole diameter = 1/2- 2B (15- 50 A)

[ Model]
A 13P~A50P-2 type ... High performance type



KZ type Equalizing valve

[ Specifications]
Primary pressure P1 = - 12 kPa
Secondary pressure P2 = 0 Pa
Hole diameter = 3/8- 3B

[ Model]
KZ-10~KZ-80 type ... High performance type



DSG Series (quick open type)

[ Features ]
It is a DC driven actuator with a built-in rectifier, so it is safe without noise and coil burnout.
It has a built-in strainer and is structured to stop inclusion such as dust at the time of piping in front of the valve.
JIS standard conduit screws are provided and electrical wiring is easy.
It has a dustproof and drip-proof construction.



MN Series (quick open type)

[ Features ]
It is a DC driven actuator with a built-in rectifier, so it is safe without noise and coil burnout.
It has a built-in strainer and is structured to stop inclusion such as dust at the time of piping in front of the valve.
JIS standard conduit screws are provided and electrical wiring is easy.
It has a dustproof and drip-proof construction.



VNA Series (quick open type)

[ Features ]
It corresponds to a wide range of gas pressure ranging from low pressure to intermediate pressure.
Easy adjustment of flow rate (calorie change), adjustable even after installation.
Structure that avoids attachment of inclusion by improvement of valve structure.
A robust dedicated terminal box equipped with JIS standard conduit screws is attached and electrical wiring is also easy.
It is a DC driven actuator with a built-in rectifier, so it is safe without noise and coil burnout.
It has a dustproof and drip-proof construction.



VLA Series (slow open type)

[ Features ]
It corresponds to a wide range of gas pressure ranging from low pressure to intermediate pressure.
Easy adjustment of flow rate (calorie change), adjustable even after installation.
Structure that avoids attachment of inclusion by improvement of valve structure.
A robust dedicated terminal box equipped with JIS standard conduit screws is attached and electrical wiring is also easy.
It is a DC driven actuator with a built-in rectifier, so it is safe without noise and coil burnout.
It has a dustproof and drip-proof construction.



J601 Series

[ Features ]
Adopt bonnet structure for coil exterior.
The coil is a commercial power supply specification of AC 100 V or 200 V.
Because it is a lead wire drawer, handling and operation is easy.
As the hole diameter series are aligned from Rc 1/4 to Rc 3/4, it is possible to select according to the pipe diameter and required flow rate.



Multi Rex AB Series

[ Features ]
It is a high withstand pressure solenoid valve.
The coil part is molded with resin and it is dustproof and dripproof.


Emergency shut-off valve

[ Features ]
w/manual set
safety shutdown valve


CMG Flow monitor

[ Features ]
The flow rate is easy to see with the red LED display. It can surely check even from a distance.
Hi (upper limit) and Lo (lower limit) of flow rate can be set.
One touch display switching of instantaneous flow rate and integrating flow meter
Separate the color of mask surface according to gas type.
(For air - Light blue, for other gases - Yellow)



CMS Mass flow meter

[ Features ]
High accuracy of ± 5 RD, high resolution of 0.1 sL / min (CMS 200 is 1 sL / min).
The model without display can be remotely displayed with the optional multi-channel display (CMW 100 A).
Model with display, equipped with abundant functions such as analog output, event output and so on.
It is not influenced by humidity, pressure, flow measurement.



CMQ Mass flow controller

[ Features ]
High-speed control with real power value of 500 ms overturning common sense is realized.
(Start control from fully closed, the set value changing, during the primary-side gas pressure fluctuation)
Low differential pressure control of 49 kPa or less is realized.
Integration of display unit and operation unit, contact input to achieve both high function and ease of use.



TBX100

[ Features ]
It is a compact turbine meter for low pressure with maximum operating pressure of 1.0 kgf / cm 2.



Membrane gas meter

[ Features ]
It is suitable for low pressure gas lightweight such as city gas, LP gas, nitrogen, air and so on.
The outer case uses aluminum die casting, and the abdominal plate uses zinc iron plate. It is lightweight, durable and can be used with confidence.
By adopting instrumental error matching device, instrumental error are stable over a wide range.



Float type area flowmeter

[ Features ]
Glass taper pipe type flowmeter, etc.
There is also a differential pressure measurement type.
There are also types of large capacity.


Pressure gauge (Micromanometer)

[ Features ]
It is a micromanometer for piping of φ75 face, 3/8 screw-in type.
Measurement range 0 - 5 Kpa, 0 - 10 Kpa,
It can correspond to each pressure.
(Dedicated adapter straight thread 3/8 → tapered screw 1/4 in the lower left of the photo)



Manostar gauge W081F (surface mount type)

[ Features ]
Connect to our company's SOM and use it for differential pressure measurement.
High pressure measurement can be done.



Pressure switch

[ Features ]
It is a compact, lightweight gas pressure, pneumatic switch that checks pressure fluctuations of gas combustion equipment.
On the left of the photo, an optional plica conduit adapter.



Inspection tap

[ Features ]
It is an inexpensive pressure measuring tube.
When removing the screw of M4 and inserting the hose, pressure inside the tube can be measured.



Inspection tap (2 stage type) (SKV-6H)

[ Features ]
Both silicone tube (inner diameter Φ 6) and rubber hose (for 3/8) can be inserted.



Inspection tap w/stop valve

[ Features ]
When removing the cap, inserting a rubber hose, the valve opens, pressure can be measured instantaneously, and the valve closes when the hose is pulled out is a one-touch type.
When the cap is tightened, the valve is completely locked.



Ring joint

[ Features ]
10φ steel pipe Joint It is possible to fix and connect the steel pipe simply by tightening the hexagon nut with metal fittings.

[φ10+1/8R , φ10*3/8R]



Control motor ECM3000

[ Features ]
The control motor ECM 3000 is an electric operating device for controlling various devices in the industrial market.
There are two types, rotation angle 90 ° type for burner control, rotation angle 160 ° type for control valve control such as cold / hot water / steam.



Control motor CN-0125

[ Features ]
The control motor is an electric operating device used for air conditioning equipment, heat treatment equipment, heating furnace, as well as air-fuel ratio control of the burner.
Control the temperature, pressure, flow rate etc. by opening and closing valves and dampers with signals of regulators etc.
In addition, it is combined with various valves, it is used for valve automation etc.



Motor setting plate

[ Features ]
It is a dedicated mounting plate for attaching a control motor that performs automatic flow control by connecting with SHOEI's (BVC) and proportional valve (SVP).
The valve locking position can be moved back and forth according to the handle position.
Plated finish.
Yamatake, Nissin Riken correspondence.




Linkage joint

[ Features ]
Variable control valves, angular fittings for connecting handle of proportional valve and operation handle of control motor.
The joint is excellent in strength. Because it is a corrosion resistant plating product, it is strong against rust.
Rubber skirt as standard equipment to prevent sticking due to entry of dust etc.
It is small, but it is an important part of commitment that other companies do not have.
* The lower left of the photo is an example of linkage joint use.



Linkage rod

[ Features ]
It is a metal rod that connects various control valves of SHOEI and handle of proportional valve and operation handle of control motor.
Corrosion resistant plated.
In addition to 300 mm, 500 mm, we will correspond length by custom order.


Sight hole

[ Features ]
It is attached for visual inspection of the state of the flame inside the furnace and the burner case.


PT1/s type screw

flange type(glass part φ65)

SAH type


Pilot holder

[ Features ]
It is a holder for attaching the pilot burner to the furnace.
15 A site hole can be installed and a flame detector can be set.



Ignition plug (spark plug)

[ Features ]
It is a tool to ignite the burner by the spark generated by the high voltage output from the igniter.
You can choose from various types according to the burner shape, including various burner exclusive items of our company.


M18

Round type straight

Round type L-bending



S7200A
Ignition transformer (Igniter)

S7200A
The S7200A is a high-performance solid state ignition transformer used for oil-fired gun type burner for business and industrial use and gas fired power burner.


G7023ZC
G7023ZC
Ignition transformer (Igniter) is AC100V ・ 200V dual use.
Since it is a wire transformer type, high energy can be obtained.



High voltage cord

[ Features ]
It is an insulated cable that connects to the secondary high voltage output of the igniter.

[ Type]
General-purpose rubber capillary covering (φ7)
Heat resistant silicon / white (φ5, φ7)


Rubber cab tire(black)

Silicon cord (white)


Connection fittings

[ Features ]
It is a metal fitting for connecting high pressure cord to spark plug.


alligator clip + Shrinkable tube

plug cap( black/ bakelight)

plug cap( white/ ceramic)


Relay fittings

[ Features ]
Metal fittings for relaying electrode rods such as Kanthal wire (for φ3, for φ4)



Kanthal wire

[ Features ]
Rod line to be used when extending the electrode (φ3, φ4)



Spark plug mounting bracket

[ Features ]
It is a mounting bracket to be used by inserting our company's φ12 insulator.
The top position of the rod can be adjusted.
The picture (lower left) is an example of plug installation.




C7027A

C7027A
Small ultravision is a compact, lightweight, socket mounted flame detector that detects ultraviolet ray of oil / gas combustion flame, and it is used in combination with various protection relays.


C7035A

C7035A
Small ultravision is a compact, lightweight, socket mounted flame detector that detects ultraviolet ray of oil / gas combustion flame, and it is used in combination with various protection relays.


AUD300C2000
Advaced UV sensor is a flame detector that detects ultraviolet light of oil / gas burner flame.
Dedicated advanced ultraviolet relay combines with AUR 300C / 350C and burner controller AUR 400C/450C and dynamically self-checks the failure of UV relay combined with UV sensor by built-in shutter drive.


M18

The frame rod detects the flame by the rectification effect between the flame and the rod.
It is used in combination with a rectifier type amplifier or various protection relays incorporating it.
(Option: M18 x 15 A bushing)


BC-R25 series(azbil)

・ Automatic ignition of gas burner, flame monitoring and fuel shutoff ensures safety.
・ It is a burner controller (combustion safety controller) for batch operation only (a device that starts and stops at least once within 24 hours).
・ New JIS standard compliant.
・ With the RS - 485 communication / PC loader function, more detailed status monitoring and troubleshooting are possible.



DBC J series(Honeywell)

・ Automatic ignition of gas burner, flame monitoring and fuel shutoff ensures safety.
・ It is a digital single burner controller for medium size combustion equipment.
・New JIS standard compliant / EN standard compliant.
・ Ultraviolet phototube or frame rod can be selected by jumper switching.
・100V or 200V type for the Japanese market.




FRS100

FRS 100 is a combustion safety controller with a start-up safe start circuit.
Ignition at startup prevents ignition and safety is ensured by interrupting the combustion system at the time of fire fighting etc. during operation.



Gas detection alarm NV-500

Combustion device Install a sensor in piping, detect gas leakage, close the gas valve, and make a circuit to issue an alarm.




seismic sensor Vibcon V-725

Insert it into the circuit which detects the earthquake and shuts off the gas valve or issues an alarm.


Temperature indicating controller

Temperature sensor is combined to automatically control the thermal power.



Program controller

Programmed input of preset temperature and time in advance enables you to control the temperature gradually.



Temperature sensor

There are various kinds from low temperature to high temperature.


Protective tube type

Sheath type


Temperature recorder

It is a device that continuously records temperature change.
(Chart paper record, digital record etc)



Long axis motor type

This series of blowers using aluminum die-cast casing is extremely simple, as it has a structure in which rotating blades (fans) are directly mounted on the shaft of the long shaft motor.
For that reason maintenance and free troubles are decreasing as well.
With multi-stage structure, high pressure, high efficiency, low noise is realized.




Turbo blower belt driven type

The blower of this series uses aluminum die casting casing, and it is placed on a common platform together with the motor.
Power is transmitted by pulleys and belts.
For this reason, we have realized various performance variations by combination of pulleys.
For the belt, use 3V-X belt with cog with high conduction efficiency.
It is a blower suitable for applications requiring high pressure with relatively small air volume.




BS series

It is a double seal ・ drain withdrawing mechanism to withstand harsh conditions such as moisture and hot air.
Because it is aluminum die-cast, it is a lightweight, compact appearance and a robust structure.
Runners are carefully balanced one by one with a dynamic balancer so it is outstanding durability with low noise.
It is possible to easily change the direction of wind discharge in four directions.


viledon filter

This is a nonwoven fabric air filter commonly used for combustion blowers.
(The picture is attached to the filter case.)



GC filter

It is a high performance filter used for ceramat burner.